{"id":40,"date":"2026-01-09T03:23:29","date_gmt":"2026-01-09T03:23:29","guid":{"rendered":"https:\/\/an991a9hy4.onrocket.site\/?p=40"},"modified":"2026-01-22T05:28:18","modified_gmt":"2026-01-22T05:28:18","slug":"tank-design-engineering","status":"publish","type":"post","link":"https:\/\/www.shijievt.com\/ms\/2026\/01\/09\/tank-design-engineering\/","title":{"rendered":"TANK DESIGN"},"content":{"rendered":"<h3 class=\"wp-block-heading\">Design Philosophy for Large Vertical Storage Tanks<\/h3>\n\n\n\n<p>Large vertical storage tanks are <strong>engineering structures<\/strong>, not standardized products.<br>Our design philosophy focuses on <strong>safety, compliance, durability, and constructability<\/strong>, ensuring that every tank performs reliably throughout its service life.<\/p>\n\n\n\n<p>Each tank is designed based on:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Project-specific operating conditions<\/li>\n\n\n\n<li>Applicable international design standards<\/li>\n\n\n\n<li>Actual construction and installation methods<\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><em>Engineering safety and long-term reliability are always prioritized over cost reduction.<\/em><\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">Applicable Design Codes and Standards<\/h3>\n\n\n\n<p>We design large vertical storage tanks in strict accordance with internationally recognized standards, including but not limited to:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong><a href=\"https:\/\/law.resource.org\/pub\/us\/cfr\/ibr\/002\/api.650.2007.pdf\" data-type=\"link\" data-id=\"https:\/\/law.resource.org\/pub\/us\/cfr\/ibr\/002\/api.650.2007.pdf\" target=\"_blank\" rel=\"noopener\">API 650<\/a><\/strong> \u2013 Welded Tanks for Oil Storage<\/li>\n\n\n\n<li><a href=\"https:\/\/standards.iteh.ai\/catalog\/standards\/cen\/12efab48-243b-49c3-a3c1-7e21ab2ba673\/en-14015-2004?srsltid=AfmBOopvDFGAdhYraxWfNTpdUX0Eowpm9CeV7EMi7PqDMi841I4I48Fh\" target=\"_blank\" rel=\"noopener\"><strong>EN 14015<\/strong> <\/a>\u2013 Aboveground Storage Tanks<\/li>\n\n\n\n<li><strong><a href=\"https:\/\/www.chinesestandard.net\/PDF.aspx\/GB50341-2014\" data-type=\"link\" data-id=\"https:\/\/www.chinesestandard.net\/PDF.aspx\/GB50341-2014\" target=\"_blank\" rel=\"noopener\">GB 50341<\/a><\/strong> \u2013 Chinese Code for Vertical Cylindrical Steel Tanks<\/li>\n<\/ul>\n\n\n\n<p>Design standards are selected based on:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Project location<\/li>\n\n\n\n<li>Stored medium<\/li>\n\n\n\n<li>Client and regulatory requirements<\/li>\n<\/ul>\n\n\n\n<p>Each design is fully compliant with the selected code, ensuring structural integrity and regulatory acceptance.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1980\" height=\"1400\" src=\"https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/5-\u53f0\u6cb9\u7f50\u56fe-\u6a21\u578b_01-1980x1400.png\" alt=\"\" class=\"wp-image-911\" srcset=\"https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/5-\u53f0\u6cb9\u7f50\u56fe-\u6a21\u578b_01-1980x1400.png 1980w, https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/5-\u53f0\u6cb9\u7f50\u56fe-\u6a21\u578b_01-300x212.png 300w, https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/5-\u53f0\u6cb9\u7f50\u56fe-\u6a21\u578b_01-768x543.png 768w, https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/5-\u53f0\u6cb9\u7f50\u56fe-\u6a21\u578b_01-1536x1086.png 1536w, https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/5-\u53f0\u6cb9\u7f50\u56fe-\u6a21\u578b_01-2048x1448.png 2048w, https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/5-\u53f0\u6cb9\u7f50\u56fe-\u6a21\u578b_01-18x12.png 18w, https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/5-\u53f0\u6cb9\u7f50\u56fe-\u6a21\u578b_01-600x424.png 600w\" sizes=\"auto, (max-width: 1980px) 100vw, 1980px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Design Inputs and Engineering Parameters<\/h3>\n\n\n\n<p>Accurate tank design begins with clearly defined technical inputs. Key design parameters include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Tank capacity, diameter, and height<\/li>\n\n\n\n<li>Stored liquid properties and operating temperature<\/li>\n\n\n\n<li>Design pressure and vacuum conditions<\/li>\n\n\n\n<li>Wind load, seismic load, and snow load<\/li>\n\n\n\n<li>Corrosion allowance and service environment<\/li>\n\n\n\n<li>Required service life and inspection class<\/li>\n<\/ul>\n\n\n\n<p>These parameters form the basis for all structural calculations and material selection.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Structural Design and Thickness Calculation<\/h3>\n\n\n\n<p>Tank shell, bottom, and roof thickness are determined through detailed engineering calculations in accordance with the selected design code.<\/p>\n\n\n\n<p>Our structural design process includes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Shell course thickness calculation<\/li>\n\n\n\n<li>Bottom plate and annular plate design<\/li>\n\n\n\n<li>Wind girder and stiffener design<\/li>\n\n\n\n<li>Roof structure load analysis<\/li>\n<\/ul>\n\n\n\n<p>All thickness values are verified to meet or exceed minimum code requirements.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><em>Every plate thickness is defined by calculation, not assumption.<\/em><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Roof, Bottom, and Accessories Design<\/h3>\n\n\n\n<p>Based on project requirements, we design and integrate different tank systems, including:<\/p>\n\n\n\n<p><strong>Roof Systems<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Fixed roof<\/li>\n\n\n\n<li>External floating roof<\/li>\n\n\n\n<li>Internal floating roof<\/li>\n<\/ul>\n\n\n\n<p><strong>Bottom Structure<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Flat bottom<\/li>\n\n\n\n<li>Annular plate reinforcement<\/li>\n\n\n\n<li>Leak detection and drainage systems<\/li>\n<\/ul>\n\n\n\n<p><strong>Accessories and Appurtenances<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Manholes and nozzles<\/li>\n\n\n\n<li>Vents and safety valves<\/li>\n\n\n\n<li>Ladders, stairways, and platforms<\/li>\n\n\n\n<li>Fire-fighting and monitoring interfaces<\/li>\n<\/ul>\n\n\n\n<p>All components are designed as an integrated system to ensure safety, accessibility, and ease of maintenance.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1980\" height=\"1400\" src=\"https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/10000m3\u6392\u7248\u56fe-\u6a21\u578b_01-1980x1400.png\" alt=\"\" class=\"wp-image-912\" srcset=\"https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/10000m3\u6392\u7248\u56fe-\u6a21\u578b_01-1980x1400.png 1980w, https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/10000m3\u6392\u7248\u56fe-\u6a21\u578b_01-300x212.png 300w, https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/10000m3\u6392\u7248\u56fe-\u6a21\u578b_01-768x543.png 768w, https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/10000m3\u6392\u7248\u56fe-\u6a21\u578b_01-1536x1086.png 1536w, https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/10000m3\u6392\u7248\u56fe-\u6a21\u578b_01-2048x1448.png 2048w, https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/10000m3\u6392\u7248\u56fe-\u6a21\u578b_01-18x12.png 18w, https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/10000m3\u6392\u7248\u56fe-\u6a21\u578b_01-600x424.png 600w\" sizes=\"auto, (max-width: 1980px) 100vw, 1980px\" \/><\/figure>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">Design Output and Engineering Deliverables<\/h3>\n\n\n\n<p>For each storage tank project, we provide complete and professional design documentation, including:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>General arrangement drawings<\/li>\n\n\n\n<li>Shell, bottom, and roof detailed drawings<\/li>\n\n\n\n<li>Nozzle and manhole layout drawings<\/li>\n\n\n\n<li>Welding details and inspection requirements<\/li>\n\n\n\n<li>Material lists and weight calculations<\/li>\n<\/ul>\n\n\n\n<p>These deliverables ensure smooth fabrication, accurate installation, and effective project control.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"553\" src=\"https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/automated-3D-tank-design-drawings.jpg\" alt=\"\" class=\"wp-image-1011\" style=\"width:770px;height:auto\" srcset=\"https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/automated-3D-tank-design-drawings.jpg 600w, https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/automated-3D-tank-design-drawings-300x277.jpg 300w, https:\/\/www.shijievt.com\/wp-content\/uploads\/2026\/01\/automated-3D-tank-design-drawings-13x12.jpg 13w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>","protected":false},"excerpt":{"rendered":"<p>Complex needs and challenges don\u2019t stand in the way of our engineers and designers. Not only do we take advantage of impressive state-of-the-art technologies; we\u2019ve also developed more than 50 in-house automated drawing routines that reduce the time it takes to detail by 50%. This efficiency saves customers significant time and money.<\/p>","protected":false},"author":1,"featured_media":42,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[20],"tags":[],"class_list":["post-40","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-what-we-do"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.shijievt.com\/ms\/wp-json\/wp\/v2\/posts\/40","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.shijievt.com\/ms\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.shijievt.com\/ms\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.shijievt.com\/ms\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.shijievt.com\/ms\/wp-json\/wp\/v2\/comments?post=40"}],"version-history":[{"count":6,"href":"https:\/\/www.shijievt.com\/ms\/wp-json\/wp\/v2\/posts\/40\/revisions"}],"predecessor-version":[{"id":1013,"href":"https:\/\/www.shijievt.com\/ms\/wp-json\/wp\/v2\/posts\/40\/revisions\/1013"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.shijievt.com\/ms\/wp-json\/wp\/v2\/media\/42"}],"wp:attachment":[{"href":"https:\/\/www.shijievt.com\/ms\/wp-json\/wp\/v2\/media?parent=40"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.shijievt.com\/ms\/wp-json\/wp\/v2\/categories?post=40"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.shijievt.com\/ms\/wp-json\/wp\/v2\/tags?post=40"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}